Signaling System Number 7 (SS7)

SS7 is the network control signaling protocol utilized by the Integrated Services
Digital Network (ISDN) services framework. ISDN control information for call handling
and network management is carried by SS7. SS7 is a large and complex network
designed to provide low latency and to have redundancy in many network elements. The
SS7 control-signaling network consists of signaling points, signaling links and signaling
transfer points. Signaling links or SS7 links interconnect signaling points. Signaling
points (SSP) use signaling to transmit and receive control information. A signaling point
that has the ability to transfer signaling messages from one link to another at level 3 (SS7
level 3 will be described in detail later) is a Single Transfer Point (STP). There is a
fourth entity, the Service Control Point (SCP), which acts as a database for the SS7
network. The STP queries the SCP to locate the destination of the calls. The design of
the SS7 protocol is such that it is independent of the underlying message transport
network. The design of the signaling network is very important in that it will directly
impact the availability of the overall system. In general, the network will be designed to
provide redundancy for signaling links and for STPs. Figure 1 shows a basic SS7
network.

Figure 1: SS7 Signaling Endpoints in a Switched-Circuit Network

A typical call can be illustrated using Figure 1. User A goes off-hook in New York
and begins dialing. User A is calling User C in San Francisco. The dialed digits are
transmitted across the local loop connection to a local switch that has signal point
functionality (SSP). The local switch translates the digits and determines the call is not
local to itself. The local switch will use its signal point functionality to signal into the
SS7 network to a Signal Transfer Point (STP). The STP queries a SCP to locate the
destination local switch. The STP signals to the destination local switch to alert it of the
incoming call. The destination local switch rings the phone of User C. User C answers
and the two local switches signal across the SS7 network and determine the bearer path
through the PSTN. Once the path is setup the call begins. When either user goes on
hook, the network signals the other end to tear down the bearer path and the call is
terminated. The worldwide SS7 network is divided into national and international levels.
This allows the numbering plans and administration to be separated.

Advertisements

, , , , , , , , , , , , , ,

  1. Eleanor Hoang

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: